UAC Berhad | UCO SolidPanel
17239
page,page-id-17239,page-child,parent-pageid-17456,page-template,page-template-full_width,page-template-full_width-php,ajax_fade,page_not_loaded,,qode_grid_1300,hide_top_bar_on_mobile_header,qode-theme-ver-9.5,wpb-js-composer js-comp-ver-4.12,vc_responsive
 

UCO SolidPanel

uco-solidpanel

PRODUCT DESCRIPTION


UCO SolidPanel is an IBS precast lightweight sandwiched panel using UCO Superflex boards as external sheaths with lightweight concrete infill. UCO SolidPanel is solid and achieves a straight, perfect wall finish. It conforms to Uniform Building By Law (UBBL) and has gone through stringent tests approved by relevant authorities such as SIRIM in Malaysia and TUV- PSB from Singapore.

ATTRIBUTES


FIRE RATED

2 hours fire rated, according to British Standard (BS 476 : Part 22 : 1987)

FAST TRACK CONSTRUCTION

Weight of walls is approximately 2-3 times lighter compared to brick walls. Density is 600 – 800 kg/m³. UCO SolidPanel can be easily and rapidly installed, cutting down construction time and cost.

FAST TRACK CONSTRUCTION

Easily and rapidly constructed, cutting down construction time and cost.

SOUND INSULATION

Good sound insulation

DURABLE

Immune to permanent water damage and impervious to high humidity/ moisture. Does not warp, crack or split easily.

THERMAL INSULATION

Good thermal insulation

CLEANER AND SAFER CONSTRUCTION

Reduces messiness at site and easy to clean up. Minimizes inconvenience to other trades compared to the labour-intensive conventional trade.

INSTALLATION PROCEDURE


solid-panel_01

STEP 1

Mark out centre line of the wall position. With the use of a laser marker or plumb line, transfer the marks onto the soffit.

solid-panel_02

STEP 2

Fix top metal track to structural support and bottom metal track onto the floor using 1 no. M6 anchor or approved Rampset / Hilti air gun nail at every 600mm centres maximum.

solid-panel_03

STEP 3

Mark and cut the panels for installation. Move the panels into position. Tilt the panels to enable top tracks to slot into the cells.

solid-panel_04

STEP 4

Plumbing and electrical services can be easily installed where required. Patch with cement mortar after installation.

solid-panel_05

STEP 5

Waterproofing to be applied onto surface at minimum 300mm height (upturned).  Waterproofing and tile adhesive procedures must strictly follow manufacturer‘s standard specifications. (Refer to Appendix)

solid-panel_06

STEP 6

For fixing with heavy anchorage, kindly refer to UAC’s recommendation:

solid-panel_07b

STEP 7

When completed, UCO SOLIDPANEL System can accept a wide range of finishes, i.e. wall coverings, paints and tile on application.

SPECIFICATION


Product
UCO SolidPanel 75T UCO SolidPanel 100T
Width (mm) 600 600
Thickness (mm) 75 100
Length (mm) 2400, 2700, 3000 2400, 2700, 3000
Weight 55 kg / m² 70 kg / m²

Fire Rated (BS 476 :

Part 22 : 1987)

2 hours 2 hours
Density 600 – 700 kg / m³ 600 – 700 kg / m³

Sound Insulation

(ISO 140 – 3 : 1995)

STC 36 – 39 STC 40 – 43